Compare Products

Hide

Clear All

VS

Home> Produk> Switch> Core/Aggregation Switches>

RG-S5300-E Series Gigabit Switches

Full Layer 2 Managed Switch with 10G SFP+ uplinks

Feature Highlights:

The RG-S5300-E series are next-generation gigabit Ethernet switches launched by Ruijie according to its design philosophy of security, high efficiency, energy saving, and independent innovation. This series can provide full gigabit access and flexibly extensible 10G uplink data exchanges. With a new hardware architecture and Ruijie's latest RGOS12.X modular OS, the RG-S5300-E series are capable of providing more resource entries, faster hardware processing, and better user experience.

 
 

Lebih banyak+

Sound Security Protection Policies

Address Resolution Protocol (ARP) viruses or attacks are a type of common and influential network attack. The RG-S5300-E series switches support ARP spoofing prevention in multiple modes. Regardless of whether clients automatically obtain addresses from the DHCP server or use static IP addresses, the RG-S5300-E series switches record clients' authentic IP+MAC addresses and compare addresses in ARP packets with recorded IP+MAC addresses when switch ports receive the ARP packets from hosts. The switches forward only ARP packets whose addresses match the recorded IP+MAC addresses and discard fake ARP packets. In this way, ARP spoofing is shielded outside the network and network users are protected from ARP virus attacks.

The RG-S5300-E series switches are capable of actively defending against various Distributed Denial of Service (DDoS) attacks on networks. Computers may be infected with viruses due to network openness or attackers may launch attacks on network devices and servers for various purposes, resulting in network unavailability. The common ARP flooding attacks can lead to the failure of the gateway to respond to requests. ICMP flooding attacks can paralyze network devices due to high CPU load. DHCP request flooding attacks deplete addresses of the DHCP server, and users cannot obtain IP addresses for network access.

The RG-S5300-E series switches provide an efficient hardware CPU protection mechanism: CPU Protect Policy (CPP). It classifies data traffic sent to the CPU, processes the traffic by queue priority, and limits the bandwidth rate as required. This protection mechanism greatly protects the CPU against illegitimate traffic occupancy, malicious attacks, and resource consumption, thereby ensuring the CPU security and protecting the switches.

The RG-S5300-E series switches adopt the innovative Network Foundation Protection Policy (NFPP) technology to limit the rate of ARP packets, ICMP requests, DHCP requests, and other packets sent to networks. The switches discard packets whose rate exceeds the threshold, identify attack behaviors, and isolate users launching attacks. In this way, the basic networks are protected from network attacks, and therefore the network stability is guaranteed.

DHCP snooping enables the RG-S5300-E series switches to receive DHCP responses only from trusted ports and prevent spoofing from unauthorized DHCP servers. With DHCP snooping, the switches dynamically monitor ARP packets, check users' IP addresses, and discard illegitimate packets that do not match bound entries, thereby effectively preventing ARP spoofing and source IP address spoofing.

Virtual Switching Unit

The RG-S5300-E series switches support the Virtual Switching Unit (VSU), in which multiple physical devices are connected and virtualized into one logical device. The devices use the same IP address, Telnet process, and command line interface (CLI) for management and support automatic version check and automatic configuration. Users need to manage only this logical device to enjoy the work efficiency and use experience brought by multiple devices.

Simplified management: Administrators can manage multiple switches in a unified manner, with no need to connect to each switch for configuration and management.

Simplified network topology: A VSU serves as a switch on a network and connects to peripheral devices through aggregate links. Therefore, no layer-2 loop exists and the Multiple Spanning Tree Protocol (MSTP) does not need to be configured. Various control protocols run on the VSU.

Fault recovery within milliseconds: A VSU connects to peripheral devices through aggregate links. If one device or member link in the VSU malfunctions, data and services can be switched to another member link within only 50–200 milliseconds.

High scalability: User devices can be added to or removed from a virtualized network in a "hot swap" manner, without affecting normal operation of other devices.

Increase in return on investment: Aggregate links used for connecting the VSU to peripheral devices not only provide redundancy links but also implement load balancing. All network devices and bandwidth resources are properly leveraged. Any 10G port can be used to build a VSU virtual network through data transmission cables. No additional cables and expansion cards are required, and the types of ports and cables are not limited. Therefore, the return on investment is best protected.

High Reliability

The Spanning Tree Protocol (STP), Rapid Spanning Tree Protocol (RSTP), and MSTP help the RG-S5300-E series switches achieve fast convergence, improve the fault tolerance capability, and ensure stable network operation and load balance of links. The switches utilize network channels appropriately to raise the utilization of redundant links.

The Virtual Router Redundancy Protocol (VRRP) helps the switches effectively ensure the network stability.

With the Rapid Link Detection Protocol (RLDP), the switches can quickly detect the link connectivity and unidirectional optical fiber links. The port loop detection function helps the switches prevent network failures caused by loops resulting from unauthorized port connection to hubs.

The RG-S5300-E series switches support the Ethernet Ring Protection Switching (ERPS) technology, which is an international layer-2 link redundancy backup protocol designed for the core Ethernet. The loop block and link recovery of ERPS are implemented on the controlling device, and non-controlling devices directly report their link status to the controlling device, without processing from other non-controlling devices. Therefore, loop disruption and recovery time of ERPS is faster than that of STP. Based on the above differences, ERPS supports link recovery within milliseconds in the ideal environment.

When STP is disabled, the Rapid Link Protection Protocol (RLDP) can still provide basic link redundancy and millisecond-level fault recovery faster than STP.

With the Bidirectional Forwarding Detection (BFD), the switches are able to detect links within milliseconds, and quickly converge routing and other services through the correlation with upper-layer routing protocols, ensuring the continuity of services.

Software-Defined Networking (SDN)

The RG-S5300-E series support OpenFlow 1.3 as the times require, and will collaborate with Ruijie's SDN controller to easily build large-scale L2/L3 networks. The switches allow you to smoothly upgrade the whole network to an SDN network and provide access control, visualized O&M, and other SDN features. The products greatly reduce network O&M costs while significantly simplifying network management.

Energy Efficiency

In response to China's call for energy efficiency, Ruijie deeply studies noise and energy consumption issues of conventional switches and integrates multiple energy-saving design ideas into the RG-S5300-E series switches. The switches reduce loud noise produced by deployment in offices and solve excessive energy consumption resulted from the large-scale deployment of access devices.

In addition, the RG-S5300-E series adopt the new-generation hardware architecture as well as advanced energy-efficient circuit design and components, to significantly save energy and lower noise. The entire series are equipped with variable-speed axial fans to intelligently control the fan speed based on the ambient temperature, which reduces the power consumption and noise while ensuring stable operation of the devices.

In the PoE networking environment, the RG-S5300-E series provide automatic PoE mode and energy-saving PoE mode to meet needs of users.

Easy Network Maintenance

The RG-S5300-E series switches support the Simple Network Management Protocol (SNMP), Remote Network Monitoring (RMON), Syslog, Sampled Flow (sFlow), log and configuration backup using USB flash drives for routine network diagnosis and maintenance. Administrators can also use CLI, Web-based management, telnet, CPE WAN Management Protocol (CWMP(TR069) based zero configuration and other methods to manage and maintain devices conveniently.

An LED Mode button is available on the panel of the switches. You can press this button to check the current communication status and PoE status of all ports on the switches.

IPv4/IPv6 Dual-stack Multi-layer Switching

The hardware of the RG-S5300-E series switches supports line-rate IPv4/IPv6 dual-stack multi-layer switching, distinguishes and processes IPv4 and IPv6 protocol packets. In that case, the switches can plan networks or maintain the network status based on IPv6 network requirements, and flexibly create IPv6 network communication solutions. The RG-S5300-E series switches support a wide range of IPv4 routing protocols, including static routing, RIP, OSPFv2, IS-ISv4 and BGP4. Users can select appropriate routing protocols based on network environments to flexibly build networks. The RG-S5300-E series switches also support abundant IPv6 routing protocols, including static routing, Routing Information Protocol next generation (RIPng), OSPFv3, IS-ISv6 and BGP4+, which can be selected flexibly to either upgrade the existing network to an IPv6 network or build a new IPv6 network.

 

Model

RG-S5300-24GT2SFP2XS-E

RG-S5300-24GT2SFP2XS-P-E

RG-S5300-48GT2SFP2XS-E

RG-S5300-24GT4XS-E

RG-S5300-24GT4XS-P-E

RG-S5300-48GT4XS-E

Basic Features

Fixed Ports

24 x 10/100/1000M adaptive electrical ports, 2 x 1G SFP ports, 2 x 1G/10G SFP+ ports (the default rate is 1Gbps)

(Note: 10G uplink port activation software license needs to purchase separately)

48 x 10/100/1000M adaptive electrical ports, 2 x 1G SFP ports, 2 x 1G/10G SFP+ ports (the default rate is 1Gbps)

(Note: 10G uplink port activation software license needs to purchase separately)

24 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports

48 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports

Switching Capacity

336 Gbps/3.36 Tbps

432 G/4.32 Tbps

336 Gbps/3.36 Tbps

432 G/4.32 Tbps

Packet Forwarding Rate

69 Mpps/126 Mpps

105 Mpps/166 Mpps

108 Mpps/126 Mpps

144 Mpps/166 Mpps

MAC Address

32K

ARP Table

4K

Routing Table Size

(IPv4/IPv6)

8K (IPv4/IPv6)

ACL Entries

In: 3,500

Out: 1,500

Software Features

802.1Q VLAN

The following are supported:

4K 802.1Q VLAN

Port-based VLAN

MAC-based VLAN

Private VLAN

Voice VLAN

GVRP

QinQ

Basic QinQ

Flexible QinQ

ACL

The following are supported:

Standard IP ACLs (IP-based hardware ACLs)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port IDs)

MAC-based extended ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Time-based ACLs

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port ID, protocol type, and time)

ACL 80

IPv6 ACLs

Global ACLs

ACL redirection

QoS

The following are supported:

Port traffic identification

Port traffic rate limiting

802.1p/DSCP/ToS traffic classification

Eight priority queues per port

SP, WRR, SP+WRR, RED/WRED queue scheduling mechanisms

Mirror

One-to-one mirroring, many-to-one mirroring, and one-to-many mirroring

RSPAN

Flow-based local and remote mirroring

DHCP

The following are supported:

DHCP server

DHCP client

DHCP snooping

DHCP relay

IPv6 DHCP snooping

IPv6 DHCP client

IPv6 DHCP relay

Multiple Spanning Tree Protocol (MSTP) Instances

65

Maximum Aggregation Port (AP)

128

Security Features

The following are supported:

3-tuple binding (IP address, MAC address, and port)

3-tuple binding (IPv6 address, MAC address, and port)

Filtering of invalid MAC addresses

Port- and MAC-based 802.1x authentication

MAB authentication

Portal authentication and Portal 2.0 authentication

ARP-check

DAI

ARP packet rate limiting

Gateway ARP spoofing prevention

Broadcast storm suppression

Hierarchical management of administrators and password protection

RADIUS and TACACS+

AAA (IPv4/IPv6) for device login management

SSH and SSH V2.0

BPDU guard

IP source guard

CPP, and NFPP

Port protection

ERPS

G.8032 v1/v2, Sing-ring, Tangent-ring, Intersecting-ring, Load balancing, compatible with products of this protocol.

PoE

The following are supported:

IEEE 802.3af and 802.3at power supply standards

Automatic and energy saving power supply management mode

Uninterrupted power supply in hot start mode

Scheduled powering on /off PoE ports on the basis of time policy

Port priority

Note: Only RG-S5300-24GT2SFP2XS-P-E and RG-S5300-24GT4XS-P-E support the PoE function.

IP Routing

The following are supported:

IPv4/IPv6 static routing

RIP, RIPng, OSPFv2, OSPFv3, BGP, and ISIS

Routing policy

IPv6

Basic Protocol

IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 ping, IPv6 Tracert, and IPv6 multicast

VSU Features

The following are supported:

VSU technology

Local stacking and remote stacking

Inter-chassis link binding in a stack

Virtualization via standard service interfaces

Zero Configuration

CPE WAN Management Protocol (CWMP(TR069))

Management Features

SNMPv1/v2c/v3, CLI(Telnet/Console), RMON(1, 2, 3, 9), SSH, Syslog, NTP/SNTP, Web, CLI(Telnet/Console), RMON, SSH, Syslog/Debug, NTP/SNTP, FTP, TFTP, Web, and sFLOW

Physical Features

Dimensions (W × D × H)

442 mm × 220 mm × 43.6 mm

Rack Height

1RU

MTBF (hours)

>200K

Power Supply

AC input:
Rated voltage range: 100 V to 240 V
Maximum voltage range: 90 V to 264 V
Frequency: 50/60 Hz

Fan

Fan speed regulating and alarm function

Power Consumption

Non PoE: ≤40 W

PoE: <410 W (PoE full load)

≤55 W

 

Non PoE: ≤40 W

PoE: <410 W (PoE full load)

≤55 W

Temperature

Operating temperature: 0oC to 45oC

Storage temperature: -40oC to 70oC

Relative Humidity

Operating humidity: 10% to 90%RH

Storage humidity: 5% to 95%RH

Operating Altitude

0m to 5,000m

Lightening Protection on Communication Port

10kV (Common Mode)

Lightning Protection on Power Port

 

Common Mode 6KV/Differential Mode 6KV

 

Model

Description

RG-S5300-24GT2SFP2XS-E

24 x 10/100/1000M adaptive electrical ports, 2 x 1G/10G SFP+ ports, 2 x 1G SFP ports (Note: 10G uplink port activation software license needs to purchase separately)

RG-S5300-24GT2SFP2XS-P-E

24 x 10/100/1000M adaptive electrical ports, 2 x 1G/10G SFP+ ports, and 2 x 1G SFP ports, supporting PoE remote power supply and the maximum PoE output power of 370 W (Note: 10G uplink port activation software license needs to purchase separately)

RG-S5300-24GT4XS-E

24 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports

RG-S5300-24GT4XS-P-E

24 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports, supporting PoE remote power supply and the maximum PoE output power of 370 W.

RG-S5300-48GT2SFP2XS-E

48 x 10/100/1000M adaptive electrical ports, 2 x 1G/10G SFP+ ports, 2 x 1G SFP ports (Note: 10G uplink port activation software license needs to purchase separately)

RG-S5300-48GT4XS-E

48 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports

RG-2XS-NPOE-LIC

(*) RG-S5300-24GT2SFP2XS-E and RG-S5300-48GT2SFP2XS-E switches with the 2XS software license support 10Gbps.

RG-2XS-POE-LIC

(*) RG-S5300-24GT2SFP2XS-E switch with the 2XS software license support 10Gbps.

Mini-GBIC-GT

1000BASE-TX, SFP Transceiver (100m).

Mini-GBIC-SX-MM850

1000BASE-SX, SFP Transceiver, SM (850nm, 500m, LC).

Mini-GBIC-LX-SM1310

1000BASE-LX, SFP Transceiver, SM (1310nm, 10km, LC).

Mini-GBIC-LH40-SM1310

1000BASE-LH, SFP Transceiver, SM (1310nm, 40km, LC).

Mini-GBIC-ZX100-SM1550

1000BASE-ZX100, SFP Transceiver, SM (1550nm, 100km, LC).

XG-SFP-SR-MM850

10GBASE-SR, SFP+ Transceiver, MM (850nm, 300m, LC)

XG-SFP-LR-SM1310

10GBASE-SR, SFP+ Transceiver (1310nm, 10km, LC)

XG-SFP-ER-SM1550

10GBASE-SR, SFP+ Transceiver (1550nm, 40km, LC)

 

(*) indicates future support.

With the highlights of high security, high efficiency, intelligence, and energy saving, the RG-S5300-E series can excellently meet networking requirements in the following scenarios:

Full gigabit access to LANs of large enterprises, institutions, and campuses, such as the LANs in government buildings, universities, and large manufacturing/energy/metallurgy/other organizations;

Gigabit access to business systems related to medical care, libraries, exhibition centers, and websites;

Access to IP phones, WLAN access points, and HD cameras;

Gigabit access to server clusters and uplink access over 10G bandwidth;

Requirements for flexible and diversified security control policies to prevent and contain network viruses and network attacks, and to provide secure access for users.

Scenario

The RG-S5300-E series serve as access switches. They network with aggregation switches deployed for buildings (RG-S5760X series) and core switches deployed for campus networks (RG-S7900E series) to provide high-performance 1000M links to the desktop and 10G links from the aggregation layer to the core layer, so as to cope with the increasing information of access users. In SDN solutions, the RG-S5300-E series are capable of providing access control, visualized O&M, and other intelligent functions.

 

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Hubungi Kami

Hubungi Kami

How can we help you?

Hubungi Kami

Get an Order help

Hubungi Kami

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey