Compare Products
Hide
VS
Core or aggregation switch for small and medium-sized networks, supporting the smooth evolution to 25G campus networks
Models
Seri
Fitur Penting
The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.
Power modules can be replaced without affecting device operation. Intelligent fan speed regulation is supported for efficient cooling,
providing dual protection for the network.
The hardware supports dual stack for high-speed switching, catering to the requirements of campus network transition from IPv4 protocol to IPv6 protocol,
with significant improvement in address table capacity and network security.
Large amounts of data from different sources are handled by CPP first to prevent direct attacks on the CPU, ensuring CPU stability under high usage,
and achieving significant improvement in the device's security performance.
Hareware Specifications |
RG-S6150-24VS8CQ-X |
RG-S6150-48VS8CQ-X |
Interface Specifications |
||
Fixed port |
24 x 10GE/25GE (license required for 25G*) SFP28 ports 8 x 40GE/100GE QSFP28 ports |
48 x 10GE/25GE (license required for 25G*) SFP28 ports 8 x 40GE/100GE QSFP28 ports |
Fan module |
4 x fan modules 3+1 redundancy, at least three fan modules required for the system Fan speed regulating and fault alarming |
|
Power module |
2 x hot-swappable power modules |
|
Fixed management port |
1 x MGMT port, 1 x console port, and 1 x USB 2.0 port |
|
System Specifications |
||
System switching capacity |
2.8 Tbps |
4 Tbps |
Number of MAC addresses |
Number of global MAC addresses: 128,000 (default) Number of static MAC addresses: 10,000 |
Number of global MAC addresses: 128,000 (default) Number of static MAC addresses: 10,000 |
ARP table size |
96,000 (default) |
96,000 (default) |
ND table size |
80,000 (default) |
80,000 (default) |
Number of IPv4 unicast routes |
350,000 (default) |
350,000 (default) |
Number of IPv4 multicast routes |
4,000 |
4,000 |
Number of IPv6 unicast routes |
65,000 (default) |
65,000 (default) |
Number of IPv6 multicast routes |
2,000 |
2,000 |
Number of ACEs |
Ingress: 28,000 Egress:4,000 |
|
Number of IGMP groups |
4,000 |
|
Number of MLD groups |
1,000 |
|
Number of VSU members |
4 |
4 |
Number of VRFs |
1,024 |
1,024 |
Dimensions and Weight |
||
Dimensions (W x D x H) |
442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) |
442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) |
Weight (four fan modules and two power modules at full load) |
10 kg (22.05 lbs) |
10 kg (22.05 lbs) |
CPU and Storage |
||
CPU |
2.2 GHz quad-core processor |
2.2 GHz quad-core processor |
Storage |
DDR4 4 GB 8 GB flash memory |
DDR4 4 GB 8 GB flash memory |
Data packet buffer |
Device switching buffer: 35 MB Switching buffer per port: 22 MB |
Device switching buffer: 35 MB Switching buffer per port: 22 MB |
Power and Consumption |
||
Maximum power consumption |
270 W |
300 W |
Maximum output power |
PA550I II-F: 90–264 V AC or 100–240 VAC, 550 W |
PA550I II-F: 90–264 V AC or 100–240 VAC, 550 W |
Rated input voltage |
AC input: 100 V AC to 240 V AC Frequency: 50/60 Hz HVDC input: 240 V DC |
|
Maximum input voltage |
AC input: 90 V AC to 264 V AC HVDC input: 192 V DC to 288 V DC |
|
Environment and Reliability |
||
MTBF |
> 200,000 hours |
> 200,000 hours |
Primary airflow |
Front-to-rear airflow |
|
Operating temperature |
0°C to 45°C (32°F to 113°F) |
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|
Operating humidity |
10% RH to 90% RH (non-condensing) |
|
Storage humidity |
5% RH to 95% RH (non-condensing) |
|
Maximum operating altitude |
5000 m (16404.20 ft.) |
5000 m (16404.20 ft.) |
Interface surge protection |
Telecom port: 4 kV (MGMT port) |
Telecom port: 4 kV (MGMT port) |
RG-S6150-X Series |
|
Feature |
Description |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
IEEE 802.1Q (supporting 4K VLANs) |
|
Maximum number of VLANs that can be created: 4,094 |
|
Voice VLAN |
|
Super-VLAN and private VLAN |
|
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment |
|
GVRP |
|
Basic QinQ and selective QinQ |
|
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
|
ERPS (G.8032) |
|
LACP (IEEE 802.3ad) |
|
LLDP/LLDP-MED |
|
IP service |
Static and dynamic ARP |
DHCP server, DHCP client, DHCP relay, and DHCP snooping |
|
DNS |
|
DHCPv6 server, DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
GRE tunnel |
|
IP routing |
Static routing |
SVI: 4k supported |
|
RIP and RIPng |
|
OSPFv2 and OSPFv3 |
|
GR |
|
IS-ISv4 and IS-ISv6 |
|
BGP4 and BGP4+ |
|
Equal and Weighted Cost Multi-Path (ECMP) |
|
Packet-based and flow-based load balancing |
|
MCE |
|
Stateless auto configuration |
|
IPv4/IPv6 VRF |
|
IPv4/IPv6 PBR |
|
Multicast |
IGMPv1/v2/v3 and IGMP proxy |
IGMPv1/v2/v3 snooping |
|
IGMP filtering and IGMP fast leave |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
PIM-SSM for IPv4 and IPv6 |
|
MSDP for inter-domain multicast |
|
MLDv1/v2 |
|
MLD snooping |
|
MSDP |
|
PIM-SMv6 |
|
Multicast source IP address check Multicast source port check |
|
Multicast querier |
|
MPLS |
MPLS L3VPN |
6PE/6VPE interconnection with IPv4/IPv6 MPLS backbone network |
|
MPLS MIB (RFC1273, 4265, 4382) |
|
ACL and QoS |
Standard IP ACLs (hardware ACLs based on IP addresses) |
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) |
|
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) |
|
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) |
|
Time-based ACLs |
|
ACL80 and IPv6 ACL |
|
ACL redirection |
|
Port traffic identification |
|
Port traffic rate limiting |
|
802.1p/DSCP/ToS traffic classification |
|
Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences |
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop, RED, and WRED |
|
Eight queues on each port |
|
Rate limiting in each queue |
|
Security |
Multi-AAA |
RADIUS and TACAS+ |
|
Filtering of invalid MAC addresses Broadcast storm suppression BPDU guard |
|
RADIUS authentication and authorization |
|
Port- and MAC address-based 802.1x authentication |
|
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication |
|
Web authentication |
|
Hypertext Transfer Protocol Secure (HTTPS) |
|
SSHv1 and SSHv2 |
|
Global IP-MAC binding |
|
ICMPv6 |
|
IPv6 addressing and Path MTU Discovery |
|
Port isolation and port security |
|
IP source guard |
|
SAVI |
|
ARP spoofing prevention |
|
CPP and NFPP |
|
Various attack defense functions including NFPP, ARP anti-spoofing, DHCP/DHCPv6 attack defense, ICMP attack defense, ND attack defense, IP scanning attack defense, and customizing attack defense packet types |
|
3-tuple binding (IP address, MAC address, and port) ARP spoofing prevention 3-tuple binding (IPv6 address, MAC address, and port) Filtering of invalid MAC addresses MAB authentication Portal authentication and Portal 2.0 authentication ARP check DAI ARP packet rate limiting Gateway ARP spoofing prevention Broadcast storm suppression SSH BPDU guard |
|
Loose and strict RPF uRPF ignoring default routes |
|
Reliability |
REUP |
ERPS (G.8032) |
|
RLDP |
|
RLDP, Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control |
|
Data Link Detection Protocol (DLDP) |
|
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
BFD |
|
Link monitoring, fault notification, and remote loopback based on 802.3ah (EFM) |
|
GR for RIP, OSPF, BGP, and other routing protocols Power modules in 1+1 redundancy mode Hot swapping of power modules and fan modules |
|
Hot swapping of fan modules |
|
Device virtualization |
VSU |
NMS and maintenance |
SPAN, RSPAN, and ERSPAN |
sFlow |
|
NTP an SNTP |
|
FTP and TFTP |
|
SNMP v1/v2/c3 |
|
RMON (1, 2, 4, 9) |
|
Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups RMON used to implement Ethernet statistics, historical statistics, and alarm functions |
|
NETCONF |
|
Flow-based mirroring, and N:1 and 1:N port mirroring |
|
CWMP |
|
gRPC |
|
OpenFlow Special 1.3 Flow table analysis defined by all protocols Transmission of specified packets to the controller Configuring the controller's IP address and port Notifying port status changes to the controller |
|
CLI (Telnet/console), SSH, Syslog, SNMP over IPv6, Telnet v6, FTP/TFTP v6, DNS v6, and NTP for IPv6 |
|
Ruijie Could-based management |
|
VXLAN |
EVPN VXLAN tunnel establishment LAN access to VXLAN IPv4 over IPv4 Distributed gateway IPv6 over IPv4 Using an SVI to connect to the VXLAN network Using a routed interface to connect to the VXLAN network Proxy ARP (replying with the actual MAC address)) ND proxy (replying with the actual MAC address) ND reply (replying with the actual MAC address) EVPN VXLAN VXLAN static route Anycast gateway VXLAN bridging mode VXLAN routing mode Proxy ARP (replying with the gateway MAC address) Configuring the UDP port number in VXLAN packets Static VXLAN tunnel creation |
Note: The item marked with the asterisk (*) will be available in the future.
The switch, expansion module, power module, and other components can be ordered as needed. Before ordering an expansion module or power module, please contact the online customer service personnel for the latest support information about the module.
Model |
Description |
RG-S6150-24VS8CQ-X |
24 x 10G/25G SFP28 ports (default: 10G; the rate can be increased to 25G with a license.) 8 x 40G/100G QSFP28 ports 4 fan modules 2 power supply module slots At least one RG-PA550I II-F power supply module needs to be purchased. |
RG-S6150-48VS8CQ-X |
48 x 10G/25G SFP28 ports (default: 10G; the rate can be increased to 25G with a license.) 8 x 40G/100G QSFP28 ports 4 fan modules 2 power supply module slots At least one RG-PA550I II-F power supply module needs to be purchased. |
RG-PA550I II-F |
550 W AC power supply module |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
XG-SFP-SR-MM850 |
10G LC interface module (62.5/125 μm: 33 m; 50/125 μm: 66 m; 300-meter transmission at modal bandwidth of 2000 MHz·km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10G LC interface module (1310 nm), 10 km, applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10G LC interface module (1550 nm), 40 km, applicable to SFP+ ports |
XG-SFP-AOC1M |
10G SFP+ fiber-optic cable, 1 m, including one cable and two interface modules |
XG-SFP-AOC3M |
10G SFP+ fiber-optic cable, 3 m, including one cable and two interface modules |
XG-SFP-AOC5M |
10G SFP+ fiber-optic cable, 5 m, including one cable and two interface modules |
VG-SFP-SR-MM850 |
25G SFP28 module, MMF, max cabling distance: 100 m |
VG-SFP-SR-MM1310 |
25G SFP28 module, SMF, max cabling distance: 10 km |
VG-SFP-AOC5M |
25G Base SFP+ fiber-optic cable (including modules on both ends), 5 m |
40G-QSFP-SR-MM850 |
40G SR multi-mode fiber module, applicable to QSFP+ ports (OM3/OM4 MPO connector, 8 core, 850-nm wave length, max cabling distance: 100 m(OM3), 150 m(OM4)) |
40G-QSFP-LR4 SM1310 |
40G LR single-mode fiber module, applicable to QSFP+ ports, max cabling distance:10 km (LC interface, 2 core, 1310-nm wave length) |
40G-AOC-5M |
40G QSFP+ fiber-optic cable, 5 m, including one cable and two interface modules |
40G-AOC-10M |
40G QSFP+ fiber-optic cable, 10 m, including one cable and two interface modules |
100G-QSFP-SR-MM850 |
100G SR fiber module, QSFP28 encapsulation, MPO connector, 850-nm wave length, max cabling distance: 100 m(OM4), 70 m (OM3) |
100G-QSFP-LR4-SM1310 |
100G LR fiber module, QSFP28 encapsulation, LC interface, 1310-nm wave length, max cabling distance: 10 km (SMF) |
100G-AOC-1M |
100G QSFP28 fiber-optic cable, 1 m, including one cable and two interface modules |
100G-AOC-5M |
100G QSFP28 fiber-optic cable, 5 m, including one cable and two interface modules |
100G-AOC-10M |
100G QSFP28 fiber-optic cable, 10 m, including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Hubungi Kami
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey